| Reset : | by booted push-button |
| Number Of Cables : | 1 |
| Terminals Description Iso N°1 : | (13-14)NO || (21-22)NC |
| Short-Circuit Protection : | 10 A cartridge fuse gG EN/IEC 60269 |
| Positive Opening : | with EN/IEC 60947-5-1 |
| Light Block Supply : | direct |
| [Ithe] Conventional Enclosed Thermal Current : | 10 A |
| Marking : | CE |
| Local Signalling : | with pilot light, red, 24...130 V |
| Net Weight : | 1.47 kg |
| [Uimp] Rated Impulse Withstand Voltage : | 6 kV EN/IEC 60947-1 |
| Trigger Cable Maximum Length : | 70 m |
| Connections - Terminals : | screw clamp terminal, 1 x 0.5...2 x 1.5 mm² |
| Contacts Type And Composition : | 2 NC + 2 NO |
| [Us] Rated Supply Voltage : | 24...130 V AC/DC |
| [Ui] Rated Insulation Voltage : | 400 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14 |
| [Ie] Rated Operational Current : | 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A |
| Contact Operation : | slow-break |
| Distance Between Cable Supports : | 5-5 m |
| Mechanical Durability : | 60000 cycles |
| Cable Entry Number : | 3 tapped entry 1/2" NPT conduit entry |
| Compatibility Code : | XY2CE |
| Body Material : | zamak |
| Trigger Cable Anchor Point : | RH side |
| Safety Reliability Data : | B10d = 300000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5 |
| Cover Material : | stainless steel |
| Tightening Torque : | 0.8-1.2 N.m |
| Maximum Resistance Across Terminals : | 25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A |
| Safety Level : | can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508 |