IEC contactor, TeSys D, nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open
Item ID #LC1D40M7Schneider Electric
IEC contactor, TeSys D, nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open
Item ID #LC1D40M7IEC contactor, TeSys D, nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open
Specifications
See all specifications| Control Circuit Type : | AC 50/60 Hz, AC 50/60 Hz |
| Control Circuit Voltage Limits : | 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz1...1.1 Uc (60-70 °C):operational AC 50/60 Hz |
| Maximum Horse Power Rating : | 10 hp at 230/240 V AC 60 Hz for 3 phase motors3 hp at 115 V AC 60 Hz for 1 phase motors5 hp at 230/240 V AC 60 Hz for 1 phase motors, 10 hp at 200/208 V AC 60 Hz for 3 phase motors30 hp at 460/480 V AC 60 Hz for 3 phase motors, 30 hp at 575/600 V AC 60 Hz for 3 phase motors |
Available quantity000
Your price
$0.00 / Each
Add to template
Product Description
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 90A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
Recommended tools
Complementary Attributes
| Control Circuit Type : | AC 50/60 Hz, AC 50/60 Hz |
| Control Circuit Voltage Limits : | 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz1...1.1 Uc (60-70 °C):operational AC 50/60 Hz |
| Maximum Horse Power Rating : | 10 hp at 230/240 V AC 60 Hz for 3 phase motors3 hp at 115 V AC 60 Hz for 1 phase motors5 hp at 230/240 V AC 60 Hz for 1 phase motors, 10 hp at 200/208 V AC 60 Hz for 3 phase motors30 hp at 460/480 V AC 60 Hz for 3 phase motors, 30 hp at 575/600 V AC 60 Hz for 3 phase motors |
