| Persona Type Ids : | BM9, EU, LC, OM, OM8, PB, SC, SI, VR |
| Persona Type Names : | Charge Point Operator, End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator, IT Channel Partner |
| Market Segmentation Id : | COMMERCIAL, INDUSTRIAL |
| Market Segmentation : | Commercial, Industrial |
| Control Type : | selector switch front panel, without test button, without test button |
| Electromagnetic Compatibility : | electrostatic discharge immunity test 6 kV in contact) level 3 IEC 61000-4-2electrostatic discharge immunity test 8 kV in air) level 3 IEC 61000-4-2susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz) level 3 IEC 61000-4-3electrical fast transient/burst immunity test 1 kV capacitive connecting clip) level 3 IEC 61000-4-4electrical fast transient/burst immunity test 2 kV direct) level 3 IEC 61000-4-4, 1.2/50 µs shock waves immunity test 1 kV differential mode) level 3 IEC 61000-4-5, 1.2/50 µs shock waves immunity test 2 kV common mode) level 3 IEC 61000-4-5conducted RF disturbances 10 V 0.15...80 MHz) level 3 IEC 61000-4-6voltage dips and interruptions immunity test 0 % 1 cycle) IEC 61000-4-11voltage dips and interruptions immunity test 70 % 25/30 cycles) IEC 61000-4-11, conducted and radiated emissionsclass B EN 55022 |
| Function Available : | A- Power on-delay relay-1 C/O, Ac- On-delay and off-delay relay w/ control signal-1 C/O, At- Power on-delay relay w/ pause/summation (Y1)-1 C/O, B- Single interval relay w/ control signal-1 C/O, Bw- Double interval relay w/ control signal-1 C/O, C- Off-delay relay w/ control signal-1 C/O, D- Symmetrical flashing relay (starting pulse-off)-1 C/O, Di- Symmetrical flashing relay (starting pulse-on)-1 C/O, H- Interval relay-1 C/O, Ht- Interval relay w/ pause/summation (Y1)-1 C/O |
| Repeat Accuracy : | +/- 0.5 % IEC 61812-1, +/- 0.5 % IEC 61812-1+/- 0.5 % IEC 61812-1, +/- 0.5 % IEC 61812-1 |
| Safety Reliability Data : | MTTFd = 296.8 years, B10d = 270000 |
| Setting Accuracy Of Time Delay : | +/- 10 % of full scale 25 °C IEC 61812-1, +/- 10 % of full scale 25 °C IEC 61812-1, +/- 10 % of full scale 25 °C IEC 61812-1+/- 10 % of full scale 25 °C IEC 61812-1, +/- 10 % of full scale 25 °C IEC 61812-1, +/- 10 % of full scale 25 °C IEC 61812-1 |
| Temperature Drift : | +/- 0.05 %/°C, +/- 0.05 %/°C |
| Time Delay Range : | 6...60 min, 6...60 s, 1...10 min, 1...10 h, 0.1...1 s, 10...100 h, 1...10 s |
| Time Delay Type : | - A- Power on-delay relay- Ac- On-delay and off-delay relay w/ control signal, - At- Power on-delay relay w/ pause/summation (Y1)- B- Single interval relay w/ control signal, - Bw- Double interval relay w/ control signal- C- Off-delay relay w/ control signal - D- relay (starting pulse-off), - Di- relay (starting pulse-on), - H- Interval relay, - Ht- Interval relay w/ pause/summation (Y1), A, Ac, At, B, Bw, C, D, Di, H, Ht, power on-delay, on-delay and, interval, off-delay, symmetrical flashing |
| Voltage Drift : | +/- 0.2 %/V, +/- 0.2 %/V |
| Connections Terminals : | , 2 x 0.2...2 x 1.5 mm² 24 AWG...16 AWG) solid without cable end, 2 x 0.2...2 x 1.5 mm² 24 AWG...16 AWG) flexible with cable end, spring terminals |
| Contacts Composition : | 1 C/O |
| Certificate Agency : | GL, cULus, CSA |
| Carbon Footprint Of The Distribution Phase A4 : | 0.06002881841570492, 0.1 kg CO2 eq. |
| Carbon Footprint Of The End Of Life Phase C1 To C4 : | 0.17936841389121552, 0.2 kg CO2 eq. |
| Carbon Footprint Of The Installation Phase A5 : | 0 kg CO2 eq., 0.0005717838897834867 |
| Carbon Footprint Of The Manufacturing Phase A1 To A3 : | 2 kg CO2 eq., 1.5565700314205309 |
| Carbon Footprint Of The Use Phase B2 B3 B4 B6 : | 41 kg CO2 eq., 40.75904111642341 |
| Local Data Status : | Publishable |
| Local Publishable Date : | 2026-07-28 |
| Return Indicator : | Y |
| Weee Scope : | Out |
| Weee Product Category : | 5 |
| Scope Perimeter : | At least in Europe |
| Eoli Availability Display : | Yes |
| End Of Life Doc Ref : | ENVEOLI121113EN |
| Reach Full Compliance Status : | Reference contains Substances of Very High Concern above the threshold |
| Reach Full Compliance Status Id : | CONTAINS_SVHC |
| Reach Compliance Directive : | Reference contains Substances of Very High Concern above the threshold |
| Rohs Eur In Scope : | No |
| Rohs Eur Status : | Compliant By Exemption |
| Rohs Eur Conformity Date : | 1243 |
| Rohs Eur Full Compliance Status : | Compliant By Exemption |
| China Rohs In Scope : | Yes |
| China Rohs Label : | 5 |
| With Recycled Cardboard : | Yes |
| Without Single Use Plastic : | Yes |
| Product Contributes To Saved And Avoided Emissions : | No |
| Tier Id : | 2 |
| Tier : | 2 |
| Function Option Id : | STANDARD |
| Function Option : | Standard |
| Product Kit Identifier : | N |
| Compatibility Code : | RE17 |
| Contacts Material : | cadmium free |
| Contacts Type And Composition : | 1 C/O |
| Creepage Distance : | 4 kV/3 IEC 60664-1 |
| Device Short Name : | RE17R |
| Dielectric Strength : | 2.5 kV 1 mA/1 minute 50 Hz IEC 61812-1 |
| Electrical Durability : | 100000 cycles resistive 8 A 250 V AC |
| Functionality : | multifunction |
| Housing Material : | polycarbonate |
| Immunity To Microbreaks : | 20 ms |
| Insulation Resistance : | 100 MOhm 500 V DC IEC 60664-1 |
| Local Signalling : | LED indicator on steady: relay energised, no timing in progressLED indicator 80 % ON and 20 % OFF flashing: timing in progressLED indicator 5 % ON and 95 % OFF pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L) |
| Marking : | CE |
| Mechanical Durability : | 10000000 cycles |
| Mounting Position : | any position in relation to normal vertical mounting plane |
| Mounting Support : | 35 mm DIN rail conforming to IEC 60715 |
| Number Of Functions : | 10 |
| Operating Rate In Hz : | 10 Hz |
| Power Consumption In Va : | 0-3 VA 240 V AC |
| Product Availability : | Non-Stock - Not normally stocked in distribution facility |
| Product Or Component Type : | modular timing relay |
| Range Of Product : | Harmony Timer Relays |
| Reset Time : | 120 ms on de-energisation typical |
| Returnability : | Yes |
| Shock Resistance : | 15 gn 11 ms IEC 60068-2-27 |
| Software Version : | v6.2.5-6 |
| Supply Frequency : | 50...60 Hz +/- 5 % |
| Sustainable Packaging : | Yes |
| Total Lifecycle Carbon Footprint : | 43 kg CO2 eq. |
| Vibration Resistance : | 20 m/s² (f= 10-150 Hz) conforming to IEC 60068-2-6 |
| Voltage Range : | 0.85...1.1 Us |
| Supply Voltage Num 3 : | 12...240 V AC/DC 50/60 Hz |
| Database Version : | 2024-01 |
| Data Source : | extrapolated product |
| Height Nominal : | 90 mm |
| Width Nominal : | 17.5 mm |
| Nbr. Of Units In Pkg. : | 1 |
| Customs Code : | 8536490065 |
| On Load Factor : | 100 % |
| Warranty In Months : | 18 |
| Functional Unit Description : | Harmony RE17 timing relay can be set between 0.1 seconds and 100 hours which has an output rating of 8A with 7.5mm wide and can be supplied with 24 V DC, 24 to 240 V AC. It also has 1 change over contact SPDT (single pole double throw). It has one of market slimmest form-factors which allowing for a flexible and easy installation on DIN rail using the same space as any modular 1-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers and product is adhering to international standards. |
| Functional Unit Quantity : | 1 |
| Functional Unit Unit : | unit |
| Reference Lifetime In Y : | 10 |
| Recyclability Potential In % : | 13 |