A time delay relay is an electromechanical or electronic device that controls the opening or closing of an electrical circuit after a predefined delay. Unlike a conventional relay, which reacts instantly to the presence or absence of a signal, a time delay relay requires a delay before activating or disconnecting the load.
Activation – When the relay receives an input signal (current or voltage), an internal system measures a programmed time.
Triggering – At the end of this delay, the relay closes or opens its contacts to control the associated device or circuit.
Deactivation – Depending on the relay type, the return to the initial state can be immediate or delayed.
In summary, the time delay relay is a key element in the automation and intelligent management of electrical circuits, optimizing safety, efficiency, and user comfort.
Schneider Electric's DIN rail time relays are designed to precisely control delays in electrical circuits and automation systems. They attach directly to a DIN rail, making them easy to integrate into electrical cabinets and panels. The range consists of several families adapted to different needs. We have the RE17, RE22, Zelio Time series and the Harmony NFC version.
Common Applications
As you know, there are several families, and we will explore each of them.
Let’s start with the RE17 series. It stands out for its ultra-compact 17.5 mm format, ideal when space is limited. These single-function models, such as on-delay or star-delta switching, offer a timing range from 0.1 seconds to 100 hours and operate with a universal supply voltage of 24 to 240 V AC/DC.
The RE22 series, slightly wider at 22.5 mm, offers dual-function models, for example on-delay and off-delay. Their timing range extends from 0.05 seconds to 300 hours. They feature a diagnostic button and can be equipped with screw or spring terminals, making them perfect for upgrading or complementing an existing installation.
The Zelio Time range meets more complex needs, with single- or multi-function timers, available in analog or digital versions. Their format varies from 17.5 mm to 45 mm, and their timing range can go from milliseconds to several days, offering high robustness for industrial environments.
Finally, the Harmony NFC version brings major innovation thanks to contactless programming via smartphone. Multi-function and universal, it allows quick and flexible configuration, particularly useful when settings need to be changed regularly. These timers cover all the classic timing functions: on-delay (TON), off-delay (TOFF), cyclic flashing, pulse, or star-delta sequence for motor starting. They are used in a wide variety of applications
| Series / Model | Width | Functions | Time Range | Supply Voltage | Key Features |
|---|---|---|---|---|---|
Series / Model RE17 | Width 17.5 mm | Functions Single function (on-delay, star/delta, etc.) | Time Range 0.1 s to 100 h | Supply Voltage 24–240 V AC/DC | Key Features Ultra-compact format, DIN rail mounting, selector adjustment, static or relay output |
Series / Model RE22 | Width 22.5 mm | Functions Dual function (Ac, Act, etc.) | Time Range 0.05 s to 300 h | Supply Voltage 24–240 V AC/DC | Key Features Diagnostic button, precise adjustment, screw or spring terminals, ideal for retrofit or addition without PLC |
Series / Model Zelio Time | Width 17.5 to 45 mm | Functions Single or multi-function | Time Range ms to several days | Supply Voltage Depending on model | Key Features Wide choice of functions, analog or digital versions, industrial robustness |
Series / Model Harmony NFC | Width 22.5 mm | Functions Programmable multi-function | Time Range ms to several days | Supply Voltage Universal | Key Features Programming via NFC smartphone, high flexibility |
Schneider Electric plug-in time relays (formerly Square D JCK or Harmony Time / Zelio range) are designed to offer a variety of timing functions in an easy-to-install (plug-in base) format. They are prized for their reliability, accuracy and modularity.
Common applications
Schneider Electric’s plug‑in time delay relays are available in several families, each designed to meet specific needs.
9050 JCK Series – A true benchmark in industrial environments, these relays stand out for their versatility and robustness. Built to withstand demanding conditions, they offer a wide range of timing modes (on‑delay, off‑delay, cyclic, etc.) and extended time ranges, allowing precise adjustment for various applications, from motor control to lighting management.
Harmony REXL (Zelio) Range – Compact and easy to integrate, these models are ideal where space is limited in an electrical cabinet or control panel. Their simple, intuitive design makes them a preferred choice for quick, reliable installations without complex settings, while maintaining accurate timing performance.
Harmony SE / TDR Models – Positioned as an intermediate solution, they combine solid functional flexibility with optimal compatibility for integration into standard modules. Suitable for both industrial and commercial applications, they offer an ideal balance between performance, size, and ease of installation.
| Series | Format | Contacts | Max Current | Current Functions | Time Range | Supply Voltage | Connection | Applications |
|---|---|---|---|---|---|---|---|---|
Series 9050JCK | Format Standard plug-in | Contacts DPDT | Max Current 10 A | Current Functions On-delay, Off-delay | Time Range 0.05 s to 10 h | Supply Voltage 24, 120, 240 V AC/DC | Connection Plug-in socket | Applications General industry |
Series Harmony REXL | Format Compact | Contacts 1 or 2 CO | Max Current 8 A | Current Functions Multifunction (on/off, cycle, interval) | Time Range 0.1 s to 100 h | Supply Voltage 12–240 V AC/DC | Connection Screw / spring | Applications Building, HVAC, automation |
Series Harmony SE | Format Standard plug-in | Contacts 1 to 2 CO | Max Current 10 A | Current Functions One-shot, Repeat cycle | Time Range 0.1 s to 999 h | Supply Voltage 24–240 V AC/DC | Connection DIN rail / panel | Applications Safety, alarm timing |
Series Harmony RE7 (plug-in) | Format Multifunction | Contacts 1 or 2 CO | Max Current 8 A | Current Functions On-delay, Off-delay, Interval, Cyclic | Time Range 0.05 s to 100 h | Supply Voltage 12–240 V AC/DC | Connection Screw | Applications Machine automation |
Schneider Electric’s panel‑mounted time delay relays provide a reliable and flexible solution for precise delay control in your automation systems. Designed for easy integration into enclosures or control panels, these relays are ideal for a wide range of applications such as motor management, HVAC systems, conveyor belts, and safety devices.
Time range : 0.02 s → 300 h
Power supply : 24 to 240 V AC/DC
Contact rating : up to 5 A
Contacts : 1 or 2 NO/NC depending on model
Format : compact 48 × 48 mm, panel‑mount
Connection : screw or spring terminals
Indicator : status LED
Operating temperature : –20 °C to +60 °C
Typical Applications
Available with extended timing ranges from 0.02 seconds to 300 hours, these relays provide precise control suitable for all applications. They support supply voltages from 24 to 240 V AC/DC, feature 1 or 2 NO/NC contacts depending on the model, and are easily mounted thanks to their standard compact panel format. Screw or spring terminals simplify installation while ensuring a secure connection, and the LED indicator clearly displays the relay’s operating status.
Robust and reliable, these relays operate within a temperature range of –20 °C to +60 °C, delivering stable performance even in demanding industrial environments. Ideal for industrial automation, HVAC system control, safety device management, or conveyor operations, they offer a versatile and durable solution.
By choosing Schneider Electric’s panel‑mounted time delay relays, you are opting for precision, reliability, and ease of integration, while benefiting from the proven quality of Schneider products for your professional applications.
| Type | Function | Advantages | Disadvantages | Applications | Voltage / Time | Ref |
|---|---|---|---|---|---|---|
Type ON-Delay Timer | Function Activates after power-on, adjustable delay | Advantages Simple, precise, easy to install on panel | Disadvantages Fixed delay if non-adjustable model | Applications Motor delayed start, command sequences | Voltage / Time 24–240 V AC/DC / 0.02 s – 300 h | Ref RE48AMH13MW, RE48ATM12MW |
Type OFF-Delay Timer | Function Deactivates after power removal, delayed switch-off | Advantages Prevents abrupt stop, easy to integrate | Disadvantages Less flexible for complex sequences | Applications Lighting delay, pump control | Voltage / Time 24–240 V AC/DC / 0.02 s – 300 h | Ref RE48AML12MW, XB5DTB22 |
Type Flasher / Blinking Timer | Function Repeating ON/OFF cycles, programmable frequency | Advantages Compact, adjustable frequency | Disadvantages Not suitable for direct high-power loads | Applications Signaling, indicator lights, cyclic control | Voltage / Time 24–230 V AC/DC / 0.5 – 10 s | Ref XB5DTGM2 |
Type One-Shot / Interval Timer | Function Single output for an adjustable duration | Advantages Precise pulse, ideal for single sequences | Disadvantages Limited to one cycle | Applications Safety, sequential operations | Voltage / Time 24–240 V AC/DC / 0.02 s – 300 h | Ref RE48AMH13MW |
Type Multifunction Timer | Function Multiple modes (ON-Delay, OFF-Delay, Flasher, Interval) | Advantages Flexible, space-saving, reduces wiring | Disadvantages Slightly more complex configuration | Applications Industrial automation, sequential machines | Voltage / Time 24–240 V AC/DC / 0.02 s – 300 h | Ref RE48AMH13MW, RE48ATM12MW |
| Type | Function | Advantages | Disadvantages | Applications | Voltage / Time | References |
|---|---|---|---|---|---|---|
Type DIN Rail ON-Delay Timer | Function Activates after power-on, adjustable delay | Advantages Easy to install on DIN rail, precise timing | Disadvantages Fixed delay if non-adjustable model | Applications Motor start delay, sequential controls | Voltage / Time 24–240 V AC/DC / 0.05 s – 100 h | References RSL1*, RSL2* |
Type DIN Rail OFF-Delay Timer | Function Deactivates after power removal, delayed switch-off | Advantages Protects equipment, easy integration | Disadvantages Less flexible for complex sequences | Applications Lighting delay, pump control | Voltage / Time 24–240 V AC/DC / 0.05 s – 100 h | References RSL3*, RSL4* |
Type Plug-In ON-Delay Timer | Function Activates after power-on, adjustable delay | Advantages Compact, easy to replace, LED indicator | Disadvantages Limited current rating | Applications Machine automation, motor start delay | Voltage / Time 24–240 V AC/DC / 0.02 s – 300 h | References RE48AMH13MW, RE48ATM12MW |
Type Plug-In OFF-Delay Timer | Function Deactivates after power removal, delayed switch-off | Advantages Compact, LED indicator | Disadvantages Less flexible for multi-cycle sequences | Applications Pump control, lighting delay | Voltage / Time 24–240 V AC/DC / 0.02 s – 300 h | References RE48AML12MW, XB5DTB22 |
Type Panel-Mounted ON-Delay Timer | Function Activates after power-on, adjustable delay | Advantages Robust, suitable for industrial panels | Disadvantages Requires panel cutout | Applications Motor control, sequential machines | Voltage / Time 24–240 V AC/DC / 0.02 s – 300 h | References RE48AMH13MW, RE48ATM12MW |
Type Panel-Mounted Multifunction Timer | Function Multiple modes (ON-Delay, OFF-Delay, Flasher, Interval) | Advantages Flexible, saves space, reduces wiring | Disadvantages Slightly more complex configuration | Applications Industrial automation, sequential processes | Voltage / Time 24–240 V AC/DC / 0.02 s – 300 h | References RE48AMH13MW, RE48ATM12MW |
For a structured summary of Tradelco's expertise, services, and positioning: