| Persona Type Ids : | BM9, EU, LC, OM, OM8, PB, SC, SI, VR |
| Persona Type Names : | Charge Point Operator, End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator, IT Channel Partner |
| Market Segmentation Id : | COMMERCIAL, INDUSTRIAL |
| Market Segmentation : | Commercial, Industrial |
| Insulation Resistance : | > 500 MOhm 500 V DC IEC 60255-5, > 500 MOhm 500 V DC IEC 60255-5, > 500 MOhm 500 V DC IEC 60255-5, > 500 MOhm 500 V DC IEC 60255-5> 500 MOhm 500 V DC IEC 60255-5, > 500 MOhm 500 V DC IEC 60255-5, > 500 MOhm 500 V DC IEC 60255-5, > 500 MOhm 500 V DC IEC 60255-5 |
| Relay Monitored Parameters : | phase failure detection (2 or more phase cut), phase sequence, phase failure detection (2 or more phase cut) |
| Response Time : | <= 130 ms (in the event of a fault), <= 130 ms (in the event of a fault)<= 130 ms (in the event of a fault), <= 130 ms (in the event of a fault) |
| Safety Reliability Data : | MTTFd = 924.6 years, B10d = 850000 |
| Voltage Detection Threshold : | < 100 V AC, < 100 V AC< 100 V AC, < 100 V AC |
| Connections Terminals : | screw connectors, screw terminals, 1 x 0.5...1 x 4 mm² 20 AWG...11 AWG) solid without cable endscrew terminals, 2 x 0.5...2 x 2.5 mm² 20 AWG...14 AWG) solid without cable endscrew terminals, 1 x 0.2...1 x 2.5 mm² 24 AWG...12 AWG) flexible with cable endscrew terminals, 2 x 0.2...2 x 1.5 mm² 24 AWG...16 AWG) flexible with cable end |
| Certificate Agency : | C-tick, GL, CSA, UL, GOST |
| Carbon Footprint Of The Distribution Phase A4 : | 0.0453964143, 0 kg CO2 eq. |
| Carbon Footprint Of The End Of Life Phase C1 To C4 : | 0.2807333167, 0.3 kg CO2 eq. |
| Carbon Footprint Of The Installation Phase A5 : | 0 kg CO2 eq., 0.0232679283 |
| Carbon Footprint Of The Manufacturing Phase A1 To A3 : | 3 kg CO2 eq., 3.2623007968 |
| Carbon Footprint Of The Use Phase B2 B3 B4 B6 : | 71 kg CO2 eq., 70.6814814815 |
| Local Data Status : | Publishable |
| Local Publishable Date : | 2026-08-10 |
| Return Indicator : | Y |
| Service Catalog Item : | Finished good |
| Weee Scope : | Out |
| Weee Product Category : | 5 |
| Scope Perimeter : | At least in Europe |
| Eoli Availability Display : | Yes |
| End Of Life Doc Ref : | ENVEOLI1601001EN |
| Reach Full Compliance Status : | Reference contains Substances of Very High Concern above the threshold |
| Reach Full Compliance Status Id : | CONTAINS_SVHC |
| Reach Compliance Directive : | Reference contains Substances of Very High Concern above the threshold |
| Rohs Eur In Scope : | No |
| Rohs Eur Status : | Compliant By Exemption |
| Rohs Eur Conformity Date : | 1918 |
| Rohs Eur Full Compliance Status : | Compliant By Exemption |
| China Rohs In Scope : | Yes |
| China Rohs Label : | 5 |
| With Recycled Cardboard : | Yes |
| Without Single Use Plastic : | Yes |
| Product Contributes To Saved And Avoided Emissions : | No |
| Tier Id : | 1 |
| Tier : | 1 |
| Function Option Id : | STANDARD |
| Function Option : | Standard |
| Product Kit Identifier : | N |
| Compatibility Code : | RM17 |
| Contacts Type And Composition : | 1 C/O |
| Control Type : | without test button |
| Dielectric Test Voltage : | 2 kV AC 50 Hz, 1 min |
| Electrical Durability : | 100000 cycles |
| Electromagnetic Compatibility : | emission standard for industrial environments conforming to IEC 61000-6-4emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3immunity for industrial environments conforming to IEC 61000-6-2 |
| Housing Material : | polycarbonate |
| Local Signalling : | LED (yellow) for relay ON |
| Marking : | CE |
| Measurement Range : | 208...480 V AC |
| Measurement Voltage Limits : | 183-528 V AC |
| Mechanical Durability : | 30000000 cycles |
| Mounting Support : | 35 mm symmetrical DIN rail conforming to IEC 60715 |
| Operating Position : | any position without derating |
| Overvoltage Category : | III conforming to IEC 60664-1 |
| Power Consumption In Va : | 0-22 VA 400 V AC 50 Hz |
| Product Availability : | Stock - Normally stocked in distribution facility |
| Product Or Component Type : | 3-phase control relay |
| Product Specific Application : | for 3-phase supply |
| Range Of Product : | Harmony Control Relays |
| Relay Name : | RM17TG |
| Relay Type : | control relay |
| Returnability : | Yes |
| Software Version : | v5.9.4 |
| Supply Frequency : | 50/60 Hz +/- 10 % |
| Supply Voltage Limits : | 183-528 V AC |
| Sustainable Packaging : | Yes |
| Switching Capacity In Va : | 1250 VA |
| Tightening Torque : | 0.6-1 N.m IEC 60947-1 |
| Time Delay Type : | without |
| Total Lifecycle Carbon Footprint : | 74 kg CO2 eq. |
| Contacts Composition : | 1 C/O |
| Measurement Range 4 : | 208...480 V AC |
| Database Version : | 2022-01 |
| Data Source : | extrapolated product |
| Height Nominal : | 90 mm |
| Height Useful : | 90 mm |
| Width Nominal : | 17.5 mm |
| Width Real : | 17.5 mm |
| Nbr. Of Units In Pkg. : | 1 |
| Customs Code : | 8536698000 |
| Warranty In Months : | 18 |
| Functional Unit Description : | Harmony RM17-TE relay allows monitoring of power supply circuits in 3-phase networks. This modular multi function 3-phase supply control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It works with power consumption of 2.7 W in 80% active mode with life span of 10 years |
| Functional Unit Quantity : | 1 |
| Functional Unit Unit : | Unit |
| Reference Lifetime In Y : | 10 |
| Energy Consumption On Product Lifetime In Kwh : | 140.16 |