| Connector Type : | 1 RJ45 for connecting Modbus serial, 1 RJ45 for connecting Modbus TCP/EtherNet/IP |
| Device Connection : | in the motor supply line, inside delta |
| Display Type : | 1 LED green and yellow)status1 LED Red)Warning/Error1 LED Yellow)ASF, 1 LED Yellow)COM, 1 LED green and yellow)NET11 LED green and red)NET2, 1 LED green and red)NET3, 1 LED green and yellow)NET4, 1 LED green and red)RUN/ERR (Module Status), 1 LED green and yellow)Ethernet link, 1 LED green and red)ETH MS (Ethernet port configuration status), 1 LED green and red)Eth NS (Ethernet network status) |
| Electromagnetic Compatibility : | conducted and radiated emissions level A conforming to IEC 60947-4-2, damped oscillating waves level 3 conforming to IEC 61000-4-18electrostatic discharge level 3 conforming to IEC 61000-4-2, immunity to electrical transients level 4 conforming to IEC 61000-4-4immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3voltage/current impulse level 3 conforming to IEC 61000-4-5immunity to conducted interference caused by radio-electrical fields level 3 conforming to EN/IEC 61000-4-6 |
| Function Available : | pre-heating, smoke extraction, second motor set, Deceleration with torque control, Braking, boost, Line contactor control, reverse contactor control, anti-jam, jog, borehole pump starting, condition monitoring, power monitoring, cybersecure firmware update |
| Marking : | CE, cULus, UKCA, RCM, CCC, ATEX, EAC, KC |
| Motor Power Kw : | 37 kW 440 V in the motor supply line heavy duty45 kW 500 V in the motor supply line heavy duty45 kW 525 V in the motor supply line heavy duty55 kW 660 V in the motor supply line heavy duty55 kW 690 V in the motor supply line heavy duty75 kW 400 V to the motor delta terminals normal duty37 kW 230 V to the motor delta terminals heavy duty55 kW 400 V to the motor delta terminals heavy duty, 22 kW 230 V in the motor supply line normal duty45 kW 400 V in the motor supply line normal duty, 45 kW 440 V in the motor supply line normal duty55 kW 500 V in the motor supply line normal duty, 55 kW 525 V in the motor supply line normal duty75 kW 660 V in the motor supply line normal duty, 75 kW 690 V in the motor supply line normal duty18.5 kW 230 V in the motor supply line heavy duty, 37 kW 400 V in the motor supply line heavy duty, 45 kW 230 V to the motor delta terminals normal duty |
| Option Card : | communication module CANopen daisy chain, communication module CANopen Sub-D, communication module CANopen open style, communication module Profibus DP V1, communication module PROFINET |
| Protection Type : | phase failure mainsthermal protection starter, thermal protection motor, current overload motor, motor underload motor, excessive acceleration time motor, motor phase loss detection motor, protection against line phase inversion mains, external thermal protection motor, protection delta inside wiring starter, short-circuit between motor phase and earth motor |
| Transmission Frame : | RTU, TCP/UDP |
| Transmission Rate : | 4.8…38.4 kbps, 100 BASE TX |
| Utilisation Category : | AC-3A, AC-53A |
| Certificate Agency : | CE, cULus, UKCA, RCM, CCC, DNV, ATEX, EAC, KC |
| Carbon Footprint Of The Distribution Phase A4 : | 1.675854202443732, 2 kg CO2 eq. |
| Carbon Footprint Of The End Of Life Phase C1 To C4 : | 13.54967047048759, 14 kg CO2 eq. |
| Carbon Footprint Of The Installation Phase A5 : | 1 kg CO2 eq., 1.097534577230263 |
| Carbon Footprint Of The Manufacturing Phase A1 To A3 : | 177 kg CO2 eq., 177.3826224613421 |
| Carbon Footprint Of The Use Phase B2 B3 B4 B6 : | 1 134 kg CO2 eq., 1134.0599709308801 |
| Local Data Status : | Publishable |
| Local Publishable Date : | 2026-03-26 |
| Pre Comm Date : | 2025-03-26 |
| Return Indicator : | Y |
| Device Type : | Soft starter - Soft starter |
| Serviceability : | No |
| Traceability : | Yes |
| Field Service Division : | IDIBS |
| Average Life Duration : | 10 year(s) |
| Weee Applicability : | Finished product |
| Weee Scope : | In |
| Weee Product Category : | 5 |
| Scope Perimeter : | At least in Europe |
| Eoli Availability Display : | Yes |
| End Of Life Doc Ref : | ENVEOLI2209015EN |
| Reach Full Compliance Status : | Reference contains Substances of Very High Concern above the threshold |
| Reach Full Compliance Status Id : | CONTAINS_SVHC |
| Reach Compliance Directive : | Reference contains Substances of Very High Concern above the threshold |
| Rohs Eur In Scope : | Yes |
| Rohs Eur Status : | Compliant By Exemption |
| Rohs Eur Conformity Date : | 2421 |
| Rohs Eur Full Compliance Status : | Compliant By Exemption |
| China Rohs In Scope : | Yes |
| China Rohs Label : | 5 |
| With Recycled Cardboard : | Yes |
| Without Single Use Plastic : | No |
| Product Contributes To Saved And Avoided Emissions : | No |
| Dangerous Goods Code : | LITHIUM METAL BATTERIES IN EQUIP. BUTTON CELL-BAT EXEMPT |
| Product Kit Identifier : | N |
| Apparent Power : | 80 VA |
| Data Format : | 8 bits, configurable odd, even or no parity 1or 2 stop |
| Device Short Name : | ATS490 |
| Display Screen Available : | true |
| Internal Bypass : | true |
| Material Declaration : | true |
| Method Of Access : | slave Modbus serial |
| Number Of Addresses : | 0-247 Modbus serial |
| Operating Position : | vertical +/- 10 degree |
| Operating Rate : | 10 cyc/h |
| Overload Current : | 400 % Ie for 13 s |
| Phase : | 3 phase |
| Power Loss Per Device Current Dependent : | 15 W |
| Power Loss Static Current Independent : | 19 W |
| Power Losses : | 1113 W during starting at 40 °C at 400% Ie |
| Product Availability : | Stock - Normally stocked in distribution facility |
| Product Destination : | asynchronous motors |
| Product Or Component Type : | soft starter |
| Product Specific Application : | process and infrastructures |
| Range Of Product : | Altivar Soft Starter ATS490 |
| Returnability : | Yes |
| Safety Function : | STO (safe torque off): SIL 1 conforming to IEC 61508STO (safe torque off): PL c/category 2 conforming to ISO 13849 |
| Safety Level : | security level (SL) 1 IEC 62443-4-2 |
| Service Factor : | 100 |
| Software Version : | v6.1 |
| Supply Frequency : | 50...60 Hz - 20...20 % |
| Sustainable Packaging : | No |
| Total Lifecycle Carbon Footprint : | 1 328 kg CO2 eq. |
| Type Of Polarization : | no impedance Modbus serial |
| Updatability : | Upgradeable through digital modules |
| Volume Of Cooling Air : | 31 m3/h |
| Weee Label : | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| With Safety Function Cybersecurity : | true |
| With Safety Function Safe Programmable Logic : | false |
| Torque Control : | true |
| Database Version : | 2023-02 |
| Data Source : | extrapolated product |
| Height Nominal : | 289 mm |
| Width Nominal : | 160 mm |
| Nbr. Of Units In Pkg. : | 1 |
| Customs Code : | 8537109170 |
| On Load Factor : | 50 % |
| With Safety Function Safe Brake Management Sbc/Sbt : | false |
| With Safety Function Safe Direction Sdi : | false |
| With Safety Function Safe Operating Stop Sos : | false |
| With Safety Function Safe Position Sp : | false |
| With Safety Function Safe Speed Monitor Ssm : | false |
| With Safety Function Safe Stop 1 Ss1 : | false |
| With Safety Function Safe Torque Off Sto : | true |
| With Safety Function Safely Limited Position Slp : | false |
| With Safety Function Safely Limited Speed Sls : | false |
| With Sft Fct Safe Stop 2 Ss : | false |
| Warranty In Months : | 18 |
| Packaging Weight In G : | 1022.4 |
| Functional Unit Description : | The aim of soft starter is to drive an asynchronous motor (squirrel cage) by limitation of the current during acceleration and deceleration phase with a torque control. It’s based on three phases dimmer with Silicon controlled rectifier (thyristor). The rating of softstarter is given by nominal current 110A in the case study which lead to drive several power motor depending of power network voltage ie 230V power motor of 30kW and 690V power motor of 90kW. Calculation of the environmental impacts is based on 10 years of product service lifetime. The usage profile taken into account is 3,6% uptime in active phase, 46,4% uptime in stand by phase and 50% in control phase. |
| Functional Unit Quantity : | 1 |
| Functional Unit Unit : | unit |
| Reference Lifetime In Y : | 10 |
| Recyclability Potential In % : | 77 |