| Persona Type Ids : | BM9, EU, LC, OM, OM8, PB, SC, SI, VR |
| Persona Type Names : | Charge Point Operator, End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator, IT Channel Partner |
| Market Segmentation Id : | COMMERCIAL, INDUSTRIAL |
| Market Segmentation : | Commercial, Industrial |
| Insulation Resistance : | > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1, > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1, > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1, > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1, > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1, > 1 MOhm 500 V DC between supply and measurement IEC 60255-5, > 1 MOhm 500 V DC between supply and measurement IEC 60255-5, > 1 MOhm 500 V DC between supply and measurement IEC 60255-5, > 1 MOhm 500 V DC between supply and measurement IEC 60255-5, > 1 MOhm 500 V DC between supply and measurement IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60664-1, > 500 MOhm 500 V DC between supply and relay output IEC 60664-1, > 500 MOhm 500 V DC between supply and relay output IEC 60664-1, > 500 MOhm 500 V DC between supply and relay output IEC 60664-1, > 500 MOhm 500 V DC between supply and relay output IEC 60664-1, > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5, > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5, > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5, > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5, > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5, > 1 MOhm 500 V DC between supply and measurement IEC 60664-1, > 1 MOhm 500 V DC between supply and measurement IEC 60664-1, > 1 MOhm 500 V DC between supply and measurement IEC 60664-1, > 1 MOhm 500 V DC between supply and measurement IEC 60664-1, > 1 MOhm 500 V DC between supply and measurement IEC 60664-1> 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1, > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1, > 1 MOhm 500 V DC between supply and measurement IEC 60255-5, > 1 MOhm 500 V DC between supply and measurement IEC 60255-5 |
| Marking : | CE : EMC 89/336/EEC, CE : 73/23/EEC |
| Measurement Accuracy : | +/- 2 °C, +/- 2 °C |
| Operating Rate : | <= 360 operations/hour full load, <= 360 operations/hour full load<= 360 operations/hour full load, <= 360 operations/hour full load |
| Relay Monitored Parameters : | under temperature: -1...11°C, over temperature: 34...46°C |
| Response Time : | <= 3.5 s + Tt (in case of temperature fault), <= 3.5 s + Tt (in case of temperature fault), <= 3.5 s (on disappearance of fault), <= 3.5 s (on disappearance of fault)<= 3.5 s + Tt (in case of temperature fault), <= 3.5 s + Tt (in case of temperature fault), <= 3.5 s (on disappearance of fault), <= 3.5 s (on disappearance of fault) |
| Status Led : | 1 LED Green power ON1 LED Yellow correct temperature (high R1), 1 LED Yellow correct temperature (low R2) |
| Utilisation Category : | AC-12 IEC 60947-5-1, AC-13 IEC 60947-5-1, AC-14 IEC 60947-5-1, AC-15 IEC 60947-5-1, DC-12 IEC 60947-5-1, DC-13 IEC 60947-5-1, DC-14 IEC 60947-5-1 |
| Connections Terminals : | screw terminals, 1 x 0.5...1 x 4 mm² 20 AWG...11 AWG) solid without cable endscrew terminals, 2 x 0.5...2 x 2.5 mm² 20 AWG...14 AWG) solid without cable endscrew terminals, 1 x 0.2...1 x 2.5 mm² 24 AWG...12 AWG) flexible with cable endscrew terminals, 2 x 0.2...2 x 1.5 mm² 24 AWG...16 AWG) flexible with cable end, screw connectors |
| Certificate Agency : | GOST, GL, C-tick, UL, CSA |
| Carbon Footprint Of The Distribution Phase A4 : | 0.016607337114601512, 0 kg CO2 eq. |
| Carbon Footprint Of The End Of Life Phase C1 To C4 : | 0.2 kg CO2 eq., 0.2384205206515416 |
| Carbon Footprint Of The Installation Phase A5 : | 0.04120758435136707, 0 kg CO2 eq. |
| Carbon Footprint Of The Manufacturing Phase A1 To A3 : | 9 kg CO2 eq., 8.551813554392087 |
| Carbon Footprint Of The Use Phase B2 B3 B4 B6 : | 20 kg CO2 eq., 20.104799999999997 |
| Local Data Status : | Publishable |
| Local Publishable Date : | 2026-08-10 |
| Return Indicator : | Y |
| Weee Scope : | Out |
| Weee Product Category : | 5 |
| Scope Perimeter : | At least in Europe |
| Eoli Availability Display : | Yes |
| End Of Life Doc Ref : | ENVEOLI1601004EN |
| Reach Full Compliance Status : | Reference contains Substances of Very High Concern above the threshold |
| Reach Full Compliance Status Id : | CONTAINS_SVHC |
| Reach Compliance Directive : | Reference contains Substances of Very High Concern above the threshold |
| Rohs Eur In Scope : | No |
| Rohs Eur Status : | Compliant By Exemption |
| Rohs Eur Conformity Date : | 1918 |
| Rohs Eur Full Compliance Status : | Compliant By Exemption |
| China Rohs In Scope : | Yes |
| China Rohs Label : | 5 |
| With Recycled Cardboard : | Yes |
| Without Single Use Plastic : | Yes |
| Product Contributes To Saved And Avoided Emissions : | No |
| Tier Id : | 1 |
| Tier : | 1 |
| Function Option Id : | STANDARD |
| Function Option : | Standard |
| Product Kit Identifier : | N |
| Compatibility Code : | RM3 |
| Contacts Material : | cadmium free |
| Contacts Type And Composition : | 1 C/O |
| Control Type : | without test button |
| Dielectric Test Voltage : | 2 kV AC 50 Hz, 1 min |
| Electrical Durability : | 100000 cycles |
| Electromagnetic Compatibility : | emission standard for industrial environments IEC 61000-6-4emission standard for residential, commercial and light-industrial environments IEC 61000-6-3immunity for industrial environments NF EN/IEC 61000-6-2 |
| Housing Material : | polycarbonate |
| Immunity To Microbreaks : | 10 ms |
| Installed Device : | Pt 100 probe cable length <= 10 m |
| Insulation : | galvanic insulation between supply and measurement |
| Measurement Range : | +/- 1...46 °C+/- 1...46 °C |
| Mechanical Durability : | 30000000 cycles |
| Mounting Support : | 35 mm symmetrical DIN rail conforming to IEC 60715 |
| Operating Position : | any position without derating |
| Overvoltage Category : | III conforming to IEC 60664-1 |
| Product Availability : | Stock - Normally stocked in distribution facility |
| Product Or Component Type : | elevator machine room temperature control relay |
| Product Specific Application : | for elevator machine rooms and 3-phase supplies |
| Range Of Product : | Harmony Control Relays |
| Relay Name : | RM35AT |
| Relay Type : | temperature control relays |
| Reset Time : | 8 s |
| Resistance Across Terminals : | 1.33 kOhm temperature |
| Returnability : | Yes |
| Shock Resistance : | 15 gn 11 ms IEC 60255-21-1 |
| Software Version : | v5.9.4 |
| Supply Frequency : | 50/60 Hz +/- 10 % |
| Supply Voltage Limits : | 20.4-264 V AC21.6-264 V DC |
| Sustainable Packaging : | Yes |
| Switching Capacity In Va : | 1250 VA |
| Temperature Probe Type : | Pt 100 - 3-wire |
| Tightening Torque : | 0.6-1 N.m IEC 60947-1 |
| Time Delay Range : | 0.1...10 s adjustable 0...10 % of the full scale value) |
| Time Delay Type : | adjustable 1...10 s Tt- time delay upon fault |
| Total Lifecycle Carbon Footprint : | 29 kg CO2 eq. |
| Vibration Resistance : | 0.35 mm (f= 5-57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-11 gn (f= 57.6-150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1 |
| Database Version : | 2022-01 |
| Data Source : | extrapolated product |
| Width Nominal : | 35 mm |
| Nbr. Of Units In Pkg. : | 1 |
| Customs Code : | 8536490075 |
| Non Dissipating Shock Wave : | 4 kV |
| Run Up Delay At Power Up : | 0.2 s |
| Warranty In Months : | 18 |
| Functional Unit Description : | RM35 relay used to measure and monitor the abnormal operating& 10conditions such as on current, voltage, frequency, phase, speed, temperature and liquid level that the machine will not be allowed to run when a fault is occurred. It allows the user to initiate the necessary corrective actions before serious and costly breakdowns can occur.This product will be in 80% active mode with power consumption of 1W during 10 years of lifetime, adhering to IEC 60255-1 standard. |
| Functional Unit Quantity : | 1 |
| Functional Unit Unit : | Unit |
| Reference Lifetime In Y : | 10 |
| Recyclability Potential In % : | 8 |