| Persona Type Ids : | BM9, EU, LC, OM, OM8, PB, SC, SI, VR |
| Persona Type Names : | Charge Point Operator, End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator, IT Channel Partner |
| Market Segmentation Id : | COMMERCIAL, INDUSTRIAL |
| Market Segmentation : | Commercial, Industrial |
| Dielectric Test Voltage : | 2 kV AC 50 Hz, 1 min IEC 60255-5, 2 kV AC 50 Hz, 1 min IEC 60664-1 |
| Insulation Resistance : | > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1, > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1, > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1, > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1, > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1, > 1 MOhm 500 V DC between supply and measurement IEC 60255-5, > 1 MOhm 500 V DC between supply and measurement IEC 60255-5, > 1 MOhm 500 V DC between supply and measurement IEC 60255-5, > 1 MOhm 500 V DC between supply and measurement IEC 60255-5, > 1 MOhm 500 V DC between supply and measurement IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60664-1, > 500 MOhm 500 V DC between supply and relay output IEC 60664-1, > 500 MOhm 500 V DC between supply and relay output IEC 60664-1, > 500 MOhm 500 V DC between supply and relay output IEC 60664-1, > 500 MOhm 500 V DC between supply and relay output IEC 60664-1, > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5, > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5, > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5, > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5, > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5, > 1 MOhm 500 V DC between supply and measurement IEC 60664-1, > 1 MOhm 500 V DC between supply and measurement IEC 60664-1, > 1 MOhm 500 V DC between supply and measurement IEC 60664-1, > 1 MOhm 500 V DC between supply and measurement IEC 60664-1, > 1 MOhm 500 V DC between supply and measurement IEC 60664-1> 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1, > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1, > 1 MOhm 500 V DC between supply and measurement IEC 60255-5, > 1 MOhm 500 V DC between supply and measurement IEC 60255-5 |
| Measurement Accuracy : | +/- 10 % of the full scale value, +/- 10 % of the full scale value |
| Measurement Error : | +/- 0.05 %/°C with temperature variation, +/- 0.05 %/°C with temperature variation, < 1 % over the whole range with voltage variation, < 1 % over the whole range with voltage variation+/- 0.05 %/°C with temperature variation, +/- 0.05 %/°C with temperature variation, < 1 % over the whole range with voltage variation, < 1 % over the whole range with voltage variation |
| Operating Rate : | <= 360 operations/hour full load, <= 360 operations/hour full load<= 360 operations/hour full load, <= 360 operations/hour full load |
| Repeat Accuracy : | +/- 0.5 % input and measurement circuit, +/- 0.5 % input and measurement circuit, +/- 2 % time delay, +/- 2 % time delay+/- 0.5 % input and measurement circuit, +/- 0.5 % input and measurement circuit, +/- 2 % time delay, +/- 2 % time delay |
| Safety Reliability Data : | B10d = 290000, MTTFd = 308.2 years |
| Connections Terminals : | screw connectors, screw terminals, 1 x 0.5...1 x 4 mm² 20 AWG...11 AWG) solid without cable endscrew terminals, 2 x 0.5...2 x 2.5 mm² 20 AWG...14 AWG) solid without cable endscrew terminals, 1 x 0.2...2 x 2.5 mm² 24 AWG...12 AWG) flexible with cable endscrew terminals, 2 x 0.2...2 x 1.5 mm² 24 AWG...16 AWG) flexible with cable end |
| Certificate Agency : | GOST, C-tick, UL, GL, CSA |
| Carbon Footprint Of The Distribution Phase A4 : | 0.017915001454333914, 0 kg CO2 eq. |
| Carbon Footprint Of The End Of Life Phase C1 To C4 : | 0.3 kg CO2 eq., 0.25719378999418263 |
| Carbon Footprint Of The Installation Phase A5 : | 0.04445227603257708, 0 kg CO2 eq. |
| Carbon Footprint Of The Manufacturing Phase A1 To A3 : | 9 kg CO2 eq., 9.225184700407212 |
| Carbon Footprint Of The Use Phase B2 B3 B4 B6 : | 40 kg CO2 eq., 40.209599999999995 |
| Local Data Status : | Publishable |
| Local Publishable Date : | 2026-08-10 |
| Return Indicator : | Y |
| Weee Scope : | Out |
| Weee Product Category : | 5 |
| Scope Perimeter : | At least in Europe |
| Eoli Availability Display : | Yes |
| End Of Life Doc Ref : | ENVEOLI1601004EN |
| Reach Full Compliance Status : | Reference contains Substances of Very High Concern above the threshold |
| Reach Full Compliance Status Id : | CONTAINS_SVHC |
| Reach Compliance Directive : | Reference contains Substances of Very High Concern above the threshold |
| Rohs Eur In Scope : | No |
| Rohs Eur Status : | Compliant By Exemption |
| Rohs Eur Conformity Date : | 1918 |
| Rohs Eur Full Compliance Status : | Compliant By Exemption |
| China Rohs In Scope : | Yes |
| China Rohs Label : | 5 |
| With Recycled Cardboard : | Yes |
| Without Single Use Plastic : | Yes |
| Product Contributes To Saved And Avoided Emissions : | No |
| Tier Id : | 1 |
| Tier : | 1 |
| Function Option Id : | STANDARD |
| Function Option : | Standard |
| Product Kit Identifier : | N |
| Compatibility Code : | RM3 |
| Contacts Type And Composition : | 2 C/O |
| Control Type : | without test button |
| Electrical Durability : | 100000 cycles |
| Electromagnetic Compatibility : | emission standard for industrial environments conforming to IEC 61000-6-4emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3immunity for industrial environments conforming to NF EN/IEC 61000-6-2 |
| Housing Material : | polycarbonate |
| Hysteresis : | 5-50 % threshold setting |
| Local Signalling : | LED (green) for power ONLED (yellow) for relay ON |
| Measurement Range : | 1...100 V AC/DC |
| Mechanical Durability : | 30000000 cycles |
| Mounting Support : | 35 mm symmetrical DIN rail conforming to IEC 60715 |
| Operating Position : | any position without derating |
| Overvoltage Category : | III conforming to IEC 60664-1 |
| Polarity : | non reversible polarity on DC supply |
| Power Consumption In Va : | 0-3.5 VA AC |
| Product Availability : | Non-Stock - Not normally stocked in distribution facility |
| Product Or Component Type : | voltage control relay |
| Quality Labels : | CE |
| Range Of Product : | Harmony Control Relays |
| Relay Monitored Parameters : | overvoltage or undervoltage detection |
| Relay Name : | RM35UA |
| Relay Type : | multifunction voltage control relay |
| Reset Time : | 1500 ms time delay |
| Resistance Across Terminals : | 110 mOhm E2-M terminals22 mOhm E1-M terminals220 mOhm E3-M terminals |
| Returnability : | Yes |
| Sensitivity Scale : | 1...10 V E1-M terminals10...100 V E3-M terminals5...50 V E2-M terminals |
| Setting Accuracy Of Time Delay : | 10 % |
| Software Version : | v5.9.4 |
| Supply Voltage Limits : | 20.4-264 V AC/DC |
| Sustainable Packaging : | Yes |
| Switching Capacity In Va : | 1250 VA |
| Threshold Setting : | 10...100 % |
| Tightening Torque : | 0.6-1 N.m IEC 60947-1 |
| Time Delay Type : | adjustable 0.3...30 s, 0 + 10 % Tt- time delay upon fault |
| Total Lifecycle Carbon Footprint : | 50 kg CO2 eq. |
| Database Version : | 2022-01 |
| Data Source : | extrapolated product |
| Height Nominal : | 90 mm |
| Height Useful : | 90 mm |
| Width Nominal : | 35 mm |
| Width Real : | 35 mm |
| Nbr. Of Units In Pkg. : | 1 |
| Customs Code : | 8536490075 |
| Run Up Delay At Power Up : | 600 ms |
| Warranty In Months : | 18 |
| Functional Unit Description : | RM35 relay used to measure and monitor the abnormal operating& 10conditions such as on current, voltage, frequency, phase, speed, temperature and liquid level that the machine will not be allowed to run when a fault is occurred. It allows the user to initiate the necessary corrective actions before serious and costly breakdowns can occur.This product will be in 80% active mode with power consumption of 1W during 10 years of lifetime, adhering to IEC 60255-1 standard. |
| Functional Unit Quantity : | 1 |
| Functional Unit Unit : | Unit |
| Reference Lifetime In Y : | 10 |
| Recyclability Potential In % : | 8 |