| Persona Type Ids : | BM9, EU, LC, OM, OM8, PB, SC, SI, VR |
| Persona Type Names : | Charge Point Operator, End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator, IT Channel Partner |
| Market Segmentation Id : | COMMERCIAL, INDUSTRIAL |
| Market Segmentation : | Commercial, Industrial |
| Control Type : | without test button |
| Coordination Type : | type 1, type 2 |
| Dielectric Strength : | 4 kV AC for input/output circuit, 4 kV AC for input or output to case |
| Electromagnetic Compatibility : | electrostatic discharge 6 kV criteria A contact discharge conforming to IEC 61000-4-2, electrostatic discharge 8 kV criteria A air discharge conforming to IEC 61000-4-2, conducted RF disturbances 10 V, 0.15...80 MHz criteria A level 3 conforming to IEC 61000-4-6, electrical fast transient/burst immunity test 2 kV, 5/100 kHz criteria B output ports conforming to IEC 61000-4-4, electrical fast transient/burst immunity test 1 kV, 5/100 kHz criteria B input ports conforming to IEC 61000-4-4, radiated radio-frequency electromagnetic field immunity test 10 V/m, 80 MHz...1 GHz criteria A conforming to IEC 61000-4-3, radiated radio-frequency electromagnetic field immunity test 3 V/m, 1.4...2 GHz criteria A conforming to IEC 61000-4-3, radiated radio-frequency electromagnetic field immunity test 1 V/m, 2...2.7 GHz criteria A conforming to IEC 61000-4-3, surge immunity test 1 kV criteria A output ports line to line conforming to IEC 61000-4-5, surge immunity test 2 kV criteria B output ports line to earth conforming to IEC 61000-4-5, radiated emission environment B for DC input supply conforming to IEC 60947-4-3, conducted emission environment B for DC input supply conforming to IEC 60947-4-3 |
| Inrush Current : | 300 A at 60 Hz |
| Motor Power Kw : | 0.37 kW/0.5 hp at 120 V AC, 1.12 kW/1.5 hp at 240 V AC, 2.24 kW/3 hp at 480 V AC |
| Mounting Support : | 35 mm symmetrical DIN rail conforming to IEC 60715 |
| Number Of Channels : | 1 |
| Product Or Component Type : | modular DIN rail relay |
| Response Time : | 0.5 cycle (turn-on), 0.5 cycle (turn-off) |
| Shock Resistance : | 50 gn for 11 ms (peak acceleration) , longitudinal position conforming to IEC 60068-2-27, 30 gn for 11 ms (peak acceleration) , vertical position conforming to IEC 60068-2-27 |
| Tightening Torque : | 13...15 lb.in for load output1.5...1.7 N.m for control input, 13...15 lb.in for control input, 1.5...1.7 N.m for load output |
| Connections Terminals : | screw terminals, clamping connection capacity:1...4 mm², AWG 18...AWG 12 for input, screw terminals, clamping connection capacity:1...6 mm², AWG 18...AWG 10 for output, screw connectors |
| Carbon Footprint Of The Distribution Phase A4 : | 0.0415452906, 0 kg CO2 eq. |
| Carbon Footprint Of The End Of Life Phase C1 To C4 : | 0 kg CO2 eq., 0.0441376943 |
| Carbon Footprint Of The Installation Phase A5 : | 0.0016556268, 0 kg CO2 eq. |
| Carbon Footprint Of The Manufacturing Phase A1 To A3 : | 4 kg CO2 eq., 3.8260283019 |
| Carbon Footprint Of The Use Phase B2 B3 B4 B6 : | 235 kg CO2 eq., 234.853376 |
| Control Circuit Voltage : | 4...32 V |
| Certificate Agency : | IEC 61373:class B: category 1, IEC 60947-4-3, IEC 62314, IEC 60950-1 |
| Local Data Status : | Publishable |
| Local Publishable Date : | 2026-03-26 |
| Return Indicator : | Y |
| Stocking Flag : | Y |
| Stock Policy : | 1 |
| Weee Scope : | Out |
| Weee Product Category : | 5 |
| Scope Perimeter : | At least in Europe |
| Reach Full Compliance Status : | Reference contains Substances of Very High Concern above the threshold |
| Reach Full Compliance Status Id : | CONTAINS_SVHC |
| Reach Compliance Directive : | Reference contains Substances of Very High Concern above the threshold |
| Rohs Eur In Scope : | No |
| Rohs Eur Status : | Compliant By Exemption |
| Rohs Eur Conformity Date : | 1930 |
| Rohs Eur Full Compliance Status : | Compliant By Exemption |
| China Rohs In Scope : | Yes |
| China Rohs Label : | 5 |
| With Recycled Cardboard : | Yes |
| Without Single Use Plastic : | Yes |
| Product Contributes To Saved And Avoided Emissions : | No |
| Tier Id : | 1 |
| Tier : | 1 |
| Function Option Id : | STANDARD |
| Function Option : | Standard |
| Product Kit Identifier : | N |
| Contact Form : | Form 5 semiconductor output DOL contactor |
| Device Short Name : | SSD1 |
| Dv Dt : | 500 V/µs off-state at maximum rated voltage |
| Flame Retardance : | V-0 conforming to UL 94 |
| Insulation Resistance : | 1000 MOhm at 500 V DC |
| Load Current : | 0.2-20 A |
| Local Signalling : | LED (green) for control voltage |
| Network Frequency : | 47...440 Hz |
| Overvoltage Category : | III |
| Phase : | 1 phase |
| Power Factor : | 0.5 with maximum load |
| Product Availability : | Stock - Normally stocked in distribution facility |
| Product Configuration Type : | relay configuration |
| Range Of Product : | Harmony Solid State Relays |
| Returnability : | Yes |
| Software Version : | EIME v5.8.1 |
| Sustainable Packaging : | Yes |
| Total Lifecycle Carbon Footprint : | 239 kg CO2 eq. |
| Vibration Resistance : | 0.75 mm (f = 10-150 Hz) conforming to IEC 60068-2-6 |
| Warranty In Months : | 18 |
| X Product Configuration Type : | relay configuration |
| Pep Code : | ENVPEP1508007_V3 |
| Database Version : | 2016-11 |
| Pep Verification Date : | 2019-12-01 |
| Pcr Version : | PCR-ed3-EN-2015 04 02 |
| Psr Version : | PSR-0005-ed2-EN-2016 03 29 |
| Type Of Verification For The Pep : | Independent internal review |
| Data Source : | extrapolated product |
| Functional-unit Description : | To switch ON/OFF electronic contact during 10 years at a 50% use rate. |
| Functional-unit Quantity : | 1 |
| Functional-unit Unit : | unité (unit) |
| Reference Lifetime, In Y : | 10 |
| Energy Consumption On Product Lifetime, In Kwh : | 479.3472 |
| Energy Model - Manufacturing [A1-a3] : | Energy model used: Mexico |
| Energy Model - Installation [A5] : | Electricity mix; AC; < 1kV; EU-27 |
| Energy Model - Use [B6] : | Electricity mix; AC; < 1kV; EU-27 |
| Energy Model - End Of Life [C1-c4] : | Electricity mix; AC; < 1kV; EU-27 |
| Height Nominal : | 95.4 mm |
| Width Nominal : | 22.5 mm |
| Air Pollution (M3) Operational Energy Use [B6] : | 10108.1216 |
| Depletion Of Abiotic Resources - Fossil Fuels (Mj) Operational Energy Use [B6] : | 2665.7152 |
| Non-hazardous Waste Disposed Of (Kg) Operational Energy Use [B6] : | 875.6416 |
| Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : | 4094.0288 |
| Total Use Of Primary Energy During The Life Cycle (Mj) Operational Energy Use [B6] : | 4690.5984 |
| Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : | 596.448 |
| Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : | 4094.0288 |
| Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : | 596.448 |
| Water Pollution (M3) Operational Energy Use [B6] : | 9691.0336 |